equa-logo

 Project cases

1Hagastaden residentials - Miljöbyggnad

Type: Residential, code compliance, labels and standards (certification)
Summary: Residential building certified according to Swedish green building system Miljöbyggnad, using dedicated IDA ICE extension. Both apartments and systems were modified as a result of the simulation model.
Read more

1Energy savings in hotel retrofit

Type: Hotel, code compliance, retrofitting
Summary: Retrofit of hotel, where Swedish building code had to be followed, meets tough requirements on energy efficiency.
Read more

0a
Free cooling of an office building

Type: Office, whole-building studies
Summary: An office building cooled with boreholes. Both borehole fields and ambient air heat exchanger could be reduced significantly in size thanks to the simulation. An office building cooled with boreholes. Both borehole fields and ambient air heat exchanger could be reduced significantly in size thanks to the simulation. An office building cooled with boreholes.
Read more

2
Fennia office building, Helsinki

Type: Office, detailed studies
Summary: Retrofit of office building with high U-values. Ceiling heating/cooling panels, integrated to Sensus-system, were carefully dimensioned and positioned, resulting in good comfort and 25-35% energy savings compared to tradition system.
Read more

1
Evaporative cooling of factory envelope

Type: Industrial, detailed studies
Summary: Evaporative cooling study of a factory envelope. A tailor-made extension for IDA ICE was developed and used. Comparison between measurement and simulation showed very good agreement.
Read more

3
Exhaust air heat pump for residentials

Type: Residential, detailed studies
Summary: Creating an advanced plant model in order to size an exhaust air heat pump in a residential building, which is connected to a district heating system.
Read more

3
Slippery floor in a floorball arena

Type: Sport, retrofitting
Summary: Retrofitting of floorball hall prevents slippery floor.
Read more

1
Monitoring and verification of the office building Hagaporten 3

Type: Office, whole-building studies
Summary: Certified EU Green Building office lowered energy use from around 100 kWh/m2, yr to below 70 by monitoring and optimizations.
Read more

0
Energy model of Mall of Scandinavia

Type: Whole-building studies, code compliance, labels and standards
Summary: A 200 000 m2 shopping mall with over 1000 zones was simulated, using IFC and parallelization. Both optimization and sizing was achieved, as well verifying the energy use for the Swedish building code and the BREEAM energy credit.
Read more

1
Natural ventilation in an office building

Type: Office, whole-building studies
Summary: AVerification of a natural ventilation concept in a 60 000 m2 office building. Studies on air quality and a coupled comfort, energy and cost investigation was performed.
Read more

 